PDUs

Items 7 to 12 of 79 total

Set Descending Direction
per page

Grid  List 

Page:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
  • Eaton Tripp Lite Series 14.4kW 208V 3PH Monitored Per-Outlet PDU - LX Interface, Gigabit, 18 Outlets, 50A CS8365C Input, LCD, 1.8 m Cord, 0U 1.8 m Height, TAA - Monitored - Hubbel CS8365C 50A - 6 x IEC 60320 C13, 12 x IEC 60320 C19 - 230 V AC - Network (R

    14.4kW 3-Phase PDU Distributes and Monitors Network-Grade Power

    This monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for your data center, computer room or high-density network closet, the PDU3EVNR6H50A features six C13 and 12 C19 208V outlets in six breakered load banks, which distribute AC power to rack equipment. Plug-lock insert sleeves are included to prevent equipment cables from becoming accidentally dislodged.

    Monitored Per-Outlet PDU Lets You Keep Track of Power Consumption in Real Time

    Not only can you remotely monitor voltage and frequency, but the PDU3EVNR6H50A also allows metering of per-phase input current, as well as output current per bank and per outlet. Banks can be individually monitored to ensure proper load balance and prevent downtime. Monitoring each outlet allows you to study power consumption trends for each connected device. This helps you detect hardware problems and network traffic bottlenecks, as well as compare power usage among various devices.

    Built-In LX Platform Network Management Card Allows Remote Access 24/7

    The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, Telnet or SSH. Full 10/100/1000 Mbps auto-sensing enables optimal communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, FTP, DHCP and NTP.

    Color Touchscreen LCD Gives You Important Data at a Glance

    An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank and per outlet with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the PDU via PowerAlert® Device Manager. If an EnviroSense2 module is connected, the LCD also displays status and environmental data, including temperature and humidity.

    Easy to Install Vertically in an EIA-Standard 19 in. Rack

    The 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A six-foot cord with a Hubbell 50A CS8365C 208V input connects the PDU to a compatible AC power source, generator or protected UPS.

    TAA-Compliant for GSA Schedule Purchases

    The PDU3EVNR6H50A is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

    Learn More

    Regular Price: $1,773.19

    Special Price $1,666.80

  • Eaton 10kW 200-240V 3PH Switched PDU, LX Interface, Gigabit, 30 Outlets, L21-30P Input, LCD, 1.8 m Cord, 0U 1.8 m Height, TAA - Switched - NEMA L21-30P - 6 x IEC 60320 C19, 24 x IEC 60320 C13 - 230 V AC - 0U - Vertical - Rack Mount - Rack-mountable - TAA

    Features

    3-Phase PDU Distributes, Monitors and Manages Network-Grade Power
    Recommended for data centers, server rooms and network closets, this switched power distribution unit provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. You can more efficiently manage network power consumption and remotely reboot locked network items without having to visit the site. Reducing the number of on-site visits can help lower the cost of data center maintenance, thus lowering the PDU's total cost of ownership.

    30 Outlets Dispense AC Power to Connected Equipment
    During normal operation, 30 individually controllable outlets-24 C13 and six C19-distribute AC power to rack equipment. Each 208/240V outlet is accompanied by an LED that illuminates when the outlet is ramped up and ready to be used. The outlets are split into three separately breakered load banks that can be individually monitored to ensure proper load levels and prevent downtime due to overload-related breaker trips. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.

    Built-In LX Platform Network Management Card Allows Remote Access 24/7
    The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The 0U PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.

    Color Touchscreen LCD Offers Important Data at a Glance
    An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 208V 3-phase PDU via mobile device. If an EnviroSense2 module is connected to the Tripp Lite vertical PDU, the LCD also displays its status and environmental data, such as temperature and humidity.

    Easy to Install Vertically in an EIA-Standard 19 in. Rack
    The 70-inch 0U PDU mounts vertically using the pre-installed toolless mounting buttons or the included brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A six-foot cord with NEMA L21-30P 3- phase input connects the PDU to a compatible AC power source, generator or protected UPS.

    TAA-Compliant for GSA Schedule Purchases
    The PDU3EVS6L2130 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

    2-Year Warranty
    The PDU3EVS6L2130 is backed by a 2-year warranty, ensuring reliability and performance.

    More from the Manufacturer

    Learn More

    Regular Price: $1,648.55

    Special Price $1,549.64

  • Eaton 10kW 200-240V 3PH Switched PDU - LX Interface, Gigabit, 30 Outlets, L21-30P Input, LCD, 3 m Cord, 0U 1.8 m Height, TAA - Switched - NEMA L21-30P - 24 x IEC 60320 C13, 6 x IEC 60320 C19 - 230 V AC - Network (RJ-45) - 0U - Vertical - Rack Mount - Rack

    The PDU3EVSR10L2130 10kW 3-Phase Switched Power Distribution Unit provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime.

    The 0U PDU features 30 switched outlets (24 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L21-30P plug connects the PDU to a compatible AC power source, generator or protected UPS.

    The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

    A color touchscreen LCD lets you toggle between menus to monitor input current level per phase, output current per load bank and per outlet with ±1% billing-grade accuracy, environmental sensor data and network information. It also generates a unique QR code to allow access to the switchable PDU through a mobile device.

    Features

    Distributes, Monitors and Manages Network-Grade AC Power

    • 10kW 200/208/240V switched PDU with 3-phase input
    • Recommended for network applications requiring individual outlet control, load shedding and remote monitoring of critical network components
    • NEMA L21-30P plug with 10 ft. cord connects to compatible AC power source
    • Firmware upgrades support future product enhancements

    30 Switched Outlets Distribute AC Power

    • 24 C13 and 6 C19 outlets split into 3 separately breakered load banks
    • Individual outlets can be remotely controlled to power up, power down, reboot or lock out devices
    • Plug-lock insert sleeves prevent cables from becoming accidentally disconnected

    Color Touchscreen LCD

    • Reports network data, including IP address, input current level per phase, and output current per load bank and per outlet with ±1% billing-grade accuracy
    • Generates unique QR code for read-only access to PowerAlert® Device Manager via mobile device
    • Full access available by logging into PowerAlert Device Manager via browser as user with read/write credentials

    Built-In LX Platform Interface

    • Allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH
    • Supports 10/100 Mbps auto-sensing for communication with an Ethernet network
    • Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities
    • No Java required

    Broad Communications Compatibility

    • Supports IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP
    • Supports automatic and manual assignment of IP address

    Easy 0U Installation in EIA-Standard 19 in. Racks

    • Mounts vertically using included toolless buttons or rack-mounting brackets
    • Included PDUMVROTATEBRKT allows mounting with rear-facing outlets

    Learn More

    Regular Price: $2,094.41

    Special Price $1,968.75

  • Eaton 10kW 200-240V 3PH Switched PDU - LX Interface, Gigabit, 30 Outlets, L21-30P Input, LCD, 1.8 m Cord, 0U 1.8 m Height, TAA - Switched - NEMA L21-30P - 6 x IEC 60320 C19, 24 x IEC 60320 C13 - 230 V AC - 0U - Vertical - Rack Mount - Rack-mountable - TAA

    The PDU3EVSR6L2130 10kW 3-Phase Switched Power Distribution Unit provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. Recommended for any IT or industrial application, it features 30 switched outlets (24 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A six-foot cord with NEMA L21-30P plug connects the PDU to a compatible AC power source, generator or protected UPS.

    The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

    A color touchscreen LCD lets you toggle between menus to monitor input and output current levels, as well as environmental sensor data and network information. It also generates a unique QR code to allow access to the switchable PDU through a mobile device.

    The 0U PDU mounts vertically in racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.

    More from the Manufacturer

    Learn More

    Regular Price: $1,864.29

    Special Price $1,752.43

  • Eaton Tripp Lite Series 14.4kW 3-Phase Local Metered PDU, 208V Outlets (36 C13, 6 C19, 3 L6-30R) Hubbell 50A CS8365C, 6 ft. (1.83 m) Cord, 0U Vertical, TAA - 6 x IEC 60320 C19, 36 x IEC 60320 C13, 3 x NEMA L6-30R - 14.40 kVA - Vertical Rackmount"

    Tripp Lite 3 phase Metered PDU / Power Distribution Units offer real-time local reporting of current levels in amps via set of 3 built-in digital meters. Enables visual monitoring of PDU current levels to preserve proper loading balance and prevent circuit overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.

    More from the Manufacturer

    Learn More

    Regular Price: $1,169.12

    Special Price $1,098.97

  • Eaton Tripp Lite Series 5.7kW 3-Phase Local Metered PDU, 208/120V Outlets (36 C13, 6 C19, 6 5-15/20R), L21-20P, 6 ft. (1.83 m) Cord, 0U Vertical, TAA - 36 x IEC 60320 C13, 6 x IEC 60320 C19, 6 x NEMA 5-15/20R - 5.70 kVA - Vertical Rackmount, Toolless-moun

    Tripp Lite 3 phase Metered PDU / Power Distribution Units offer real-time local reporting of current levels in amps via set of 3 built-in digital meters. Enables visual monitoring of PDU current levels to preserve proper loading balance and prevent circuit overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.

    More from the Manufacturer

    Learn More

    Regular Price: $617.77

    Special Price $580.70

Items 7 to 12 of 79 total

Set Descending Direction
per page

Grid  List 

Page:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5