PDUs
-
Server Technology PRO2 42-Outlets PDU - Switched
Server Technology PRO2 42-Outlets PDU - Switched Learn More$3,981.31 -
Server Technology C2W42CE-DQME2M00 42-Outlets PDU - Switched - IEC 60309 60A - 42
Server Technology C2W42CE-DQME2M00 42-Outlets PDU - Switched - IEC 60309 60A - 42 Learn More$3,981.31 -
Server Technology PRO2 48-Outelts PDU - Switched - 18 x IEC 60320 C13, 18 x CX
Server Technology PRO2 48-Outelts PDU - Switched - 18 x IEC 60320 C13, 18 x CX Learn More$4,699.47 -
Server Technology PRO2 C2W54CE-4PAE2M00 54-Outlets PDU - Switched - IEC 60309 3P+N+PE - 54
Server Technology PRO2 C2W54CE-4PAE2M00 54-Outlets PDU - Switched - IEC 60309 3P+N+PE - 54 Learn More$4,337.97 -
Server Technology Smart PDU - 17.3kW, C1S42CA-DQME2700 - Monitored - IEC 60309 3P+G - 42 x IEC 60320 C13 - 230 V AC - Network (RJ-45) - Rack-mountable
The Server Technology® PRO1 Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO1 Smart "Master" PDU can be connected to as many as three (with optional module) PRO1 Smart "Link" PDU to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
Learn More$3,344.16 -
Server Technology Smart PDU - 17.3kW, C1S42CA-YQME2700 - Monitored - IEC 60309 3P+N+G 9Hr 60A - 42 x IEC 60320 C13 - 208 V - Network (RJ-45) - Cabinet-mountable, Rack-mountable - Rack/Tower
The Server Technology® PRO1 Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO1 Smart Master" PDU can be connected to as many as three (with optional module) PRO1 Smart "Link"? PDU to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration."
Learn More$3,344.16










