Eaton Tripp Lite Series 7.4kW 200-240V Single-Phase ATS/Monitored PDU - 16 C13 & 2 C19 Outlets, Dual IEC 309 32A Blue Inputs, 3 m Cords, 2U, TAA - Monitored - IEC-309 32A BLUE (2P+E) - 16 x IEC 60320 C13, 2 x IEC 60320 C19 - 230 V AC - Network (RJ-45) - 2

ATS PDU allows real-time current metering and remote power monitoring to help prevent circuit overloads and ensure proper load balance.

Features Single-Phase 32A 200-240V ATS PDU Distributes and Monitors Network-Grade Power in Real Time

This monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via its built-in network interface. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMNH32HVAT2 features 16 C13 and 2 C19 outlets in two load banks, each bank protected by a 20A circuit breaker. Dual three-meter power cords with IEC 309 32A Blue inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources.

Switches from Primary to Secondary Power Source in Milliseconds

Dynamic solid-state automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 1-5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.

Built-In LX Platform Network Management Card Allows Remote Access 24/7

The Java-free HTML5-based WEBCARDLX network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. The latest version of PowerAlert Device Manager (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite's PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations.

Digital Load Meter Helps Prevent Potentially Expensive Overloads

A digital ammeter reports the total load for all connected equipment in amps and kilowatts. Monitoring capacity helps ensure load levels remain well below maximum capacity levels with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low. Current monitoring provides 1% billing grade accuracy

Mounts into 2U of Rack Space or on a Wall

Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall or under a counter.

TAA-Compliant for GSA Schedule Purchases

The PDUMNH32HVAT2 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Availability: Call or email

$1,424.00
$1,424.00

Fast shipping on all in-stock products

Quick turnaround on RFQs - email us today.

Buy from a certified veteran-owned small business (VOSB)

Questions? Call customer service at 503-208-8410.

Description

Details

Eaton Tripp Lite Series 7.4kW 200-240V Single-Phase ATS/Monitored PDU - 16 C13 & 2 C19 Outlets, Dual IEC 309 32A Blue Inputs, 3 m Cords, 2U, TAA - Monitored - IEC-309 32A BLUE (2P+E) - 16 x IEC 60320 C13, 2 x IEC 60320 C19 - 230 V AC - Network (RJ-45) - 2U - Wall-mountable, Rack-mountable - TAA Compliant

OVERVIEW:

  • Limited Warranty : 2 Year
  • PDU Type : Monitored
  • Input Voltage : 230 V AC
  • Package Contents :
    • PDUMNH32HVAT2 18-Outlets PDU
    • Configuration Cable, USB-A to USB Micro-B
    • Rack-Mounting Hardware
    • Installable plug-Retention Sleeves
    • Cable Ties
    • Owner's Manual
  • Management :
    • Web Browser
    • SNMP
    • Telnet
    • SSH
  • Network (RJ-45) : Yes
  • Phase : Single Phase
  • Output Voltage : 230 V AC
  • Output Voltage : 220 V AC
  • Output Voltage : 200 V AC
  • Mount Type : Rack-mountable
  • Mount Type : Wall-mountable
  • Plug/Connector Type : IEC-309 32A BLUE (2P+E)
  • Country of Origin : Taiwan
  • Plug/Connector Detail : 2 x IEC 60309 32A BLUE (2P+E)
  • TAA Compliant : Yes
  • Receptacle Type : IEC 60320 C19
  • Receptacle Type : IEC 60320 C13
  • Rack Height : 2U
  • Receptacle Detail : 2 x IEC 60320 C19
  • Receptacle Detail : 16 x IEC 60320 C13
  • Power Rating (Watt) : 7400 W
  • Input Current : 32 A
  • Height : 3.5"
  • Protection Type : Overload Protection
  • Width : 17.5"
  • Depth : 12.5"
  • Environmental Compliance : Restriction of Hazardous Substances (RoHS)
  • Weight (Approximate) : 13.70 lb
  • Additional Info

    Additional Info

    SKU 01731PDUMNH32HVAT2-BF
    Weight 13.7000
    Is Featured N/A
    Manufacturer Tripp Lite by Eaton
    Manufacturer Part Number PDUMNH32HVAT2
    Width 17.5"
    Length 1
    Height 3.5"
    Product ID 01731PDUMNH32HVAT2
    UNSPSC N/A
    Other Part Number N/A